    Iron Planet Hobbies
    Multi-Protocol DCC Command Station
    This is a very easy to use basic set but easily expandable. It comes with everything you need to get started with DCC. Simply unhook your current DC power pack and connect the DCC controller and you are up and running.
    Features:
    North American & EU Power Supply Included
    USB Built In - For JMRI, Rocrail, TC, Etc...
    WiFi Built In - Smartphones, Tablets, WiFi Throttles (Roco Z71 Phone and Tablet Apps & WLANmaus)
    ROCO Z21 App & Throttle support
    LAN Port Built In - Easy Computer and Router Networking
    Programming Track Output - Easily Adjust Your Programming Track Voltage (No Extra Booster Needed For Sound
    Equipped Engines)
    IR Sensor - For
    Infrared Equipped Throttles
    On Board Easy Stop & Go Buttons For Track Power
    Easy To Use GUI For Your PC - Easy Decoder Programming, Setting Board Id's, Monitoring Occupancy Feedback, Booster Stats ex. Load, Temperature, Etc...
    RailCom - Use Id tags on your JMRI, Rocrail, Etc..., Panel To See What Loco Is In A Specific Block - Great For Dispatchers And Hidden Staging Yards
    POM Read Back When Used With The Digikeijs DR5088RC
    Keep Your LocoNet Clean With Separate LocoNet Connections For Your Boosters (DB150, DB210, Etc..) and Other Devices (UP5, UR92, DS64, SE8C, BDL168, Etc...)
    XpressNet - Easily Connect X-Bus Components From Lenz, CVP Including Wireless Receivers And Throttles (CVP OPS T1300)
    XN, FB, PB & RS Bus Connections
    LocoNet V2.0 For Extended Slots
    Support For Arduino Boards
    Multi Colored LED Indication Lights
    USB Cable And Power Supply Included
    Piko SmartController Light
    Why is this such a great deal? Let's Compare:
    5 - Average Command Station
    - Average USB Computer Connection Device
    - Average Computer Router
    - Programming Track Booster
    - Average Power Supply
    5 - Average Throttle
    5 - Total For Others without Shipping!
    Compatibility:
    Digitrax - All Current Products
    Lenz
    CVP Products - Xpressnet Lenz compatible receivers, throttles, etc...
    Roco - Including all web, smart phone and tablet apps. Plus the Z71 WiFi throttle.
    Piko
    ProtoThrottle
    Massoth
    ESU Mobile Control II - Requires LNWI or JMRI
    Uhlenbrock
    And More
    DR5000 Multi-bus central features
    Connection options:
    Standard:
    USB
    - Communication with computer/control program;
    - Protocol L.NET or XpressNet V3;
    - Virtual COM-port, speed 9600, 19200, 38400, 56800 of 115200 Baud.
    - Firmware updates
    L.NET T
    - Interface for L.NET devices (Controllers, Feedback modules etc.)
    L-NET B
    - Interface for L.NET devices: (manual-)Controllers, Feedback modules etc. Max 12v/1000mA power;
    - Interface for L.NET devices including boosters (rail-sync). Max 12v/600mA power;
    X-BUS/R-BUS
    - Interface for XpressNet devices: MultiMaus, LH100 etc. Max 12v/1000mA power;
    - Interface for R-BUS feedback modules.
    B-BUS
    - Interface for ROCO Boosters, e.g. the MultiMaus boosters 10764 lan as a booster together with the DR5000!
    RS-BUS
    - Interface for Lenz-RS-Bus feedback modules.
    ext88N
    - Interface for s88N feedback modules. Max 16 x 16 input modules (256 inputs);
    - Interface for DR502xEXT modules (bi-directioneel).
    Track-Output
    - DCC rail-output. Max 19V/3.2Amp. Lower voltages by other power supply. Min 14V.
    Program-Track
    - DCC programming output. Max 19V/800mA.
    Automatically switches from Track-Out to Program mode so the programming rail can also be used.
    LAN
    - 100baseT Ethernet. Can be connected to a local network via DHCP.
    WiFi/WLAN
    - bgn Wireless network via internal antenna.
    - Both networks can be accessed via UDP / IP and TCP / IP;
    - Protocols: Lenz XpressNet and/or L.NET-TCP/IP;
    - Wifi/LAN settings can be changed via a web-interface;
    - The WiFi / LAN module can serve as an AP (access point) as well as a router between the DR5000 and WiFi home network (LAN).
    Control:
    Stop
    - Disable Rail output.
    Go
    - Enable Rail output
    IR-Throttle
    - IR receiver compatible with Uhlenbrock IRIS and Piko DigiFern (or other RC5/36Khz remotecontrols).
    - 4 channels, per channel directly to be controlled/switched, 1 lok and 4 switches.
    - Further control possible through X-BUS and/or L.NET (manual)controls,
    the DR502xEXT modules or via the USB/LAN/Wifi interfaces.
    LEDs:
    STATUS
    - Power: Power supply present; Programming track indicator
    - Load: Ouput load. Intensity is increased with the load.
    off = no load, on is is 3.15Amp;
    - Short: Short circuit. Blink Code defines the bus caused the short circuit;
    Continue on is Track-Out
    USB
    - TX: Data is sent to the computer;
    - RX: Data is received from the computer.
    INFRARED
    - RX: Valid IR data is being received.
    X-BUS
    - TX: Data is being send to the X-BUS
    - RX: Data is being received from the X-BUS.
    STOP
    - The signals to Track-Out and the booster connection are off.
    GO
    - The signals to Track-Out and the booster connection are ON.
    L.NET
    - TX: Data is sent to the L.NET;
    - RX: Data is being received from L.NET
    ext88
    - There is at least one input on the s88 bus active;
    Intensity increases with the number of active inputs.
    WiFi
    - Active: The Wifi Network is active.
    LAN
    - Link: The LAN is connected and connected to a switch / hub / router.
    ROUTER
    - Status: The internal router is active.
    DCC:
    Locos
    - 126 simultaneous operation / control of locos;
    - F0 - F28;
    - 14/28/128 levels;
    - Long and short addresses. (9999 for long, Maximum short addresses to be set from 0-127)
    Switches
    - 2048 switches;
    - Offset +4/-4 for MultiMaus compatibility
    General:
    Feedback
    - 2048 feedback, which is the total of all possible buses.
    A smaller maximum could occur per bus
    - Feedbacks from combining all buses in one series of 1-2048
    Protocol conversion
    - All protocols are translated to the DR.Cmd internal protocol.
    Every Bus/Connection receives specific and relevant data from the internal protocol.
    Power Supply
    - Modern, low-loss switching external power supply.
    Update Info:
    -General:
    -- DR5000 can save loco settings (speed, direction and functions) when pressing the STOP button, at startup, DR5000 will readback those settings when enabled
    - RailCom:
    -- Prepared for DR5088RC to read back POM commands
    -XpressNet:
    -- Added option to set 'Report feedback from' to report Feedback and not Turnout status. Status requests for module >= "Report feedback from" are reported as Feedback, below that Turnouts are reported (as of Lenz spec's)
    -- Fixed bug caused by stray MultiMaus(r) 'power off' commands
    - ext88N
    -- Enabled the bi-directional features of the Digikeijs ext88 bus
    -- up to 8 'Control Modules' may be defined and connected, preparation for future DR5027, DR5028, DR5029 control modules
    -LocoNet
    -- Implemented LocoNet V 2.0 (extended slots)
    -- Implemented Uhlenbrock(r) special commands for connecting IB-Control and IB's in slave mode
    -- Revised LocoNet timing to enable older (very old) FRED devices and other 'slower' (Uhlenbrock) LocoNet devices
    -- Added "LocoNet over TCP/IP binary" protocol for LAN/WiFi connections
    -DCC
    -- relaxed 'one-bit' timing to enable use of DIY projects based upon Arduinos
    -- Implemented separate Speedstep settings for any address
    RS-Bus
    -- Implemented RS bus feedback.
    -- Added special timing option for LDT RS modules
    Config App 1.2.3.
    - LAN/WiFi
    -- Added "LocoNet over TCP/IP binary" protocol for LAN/WiFi connections
    - ext88N
    -- Added configuration page for ext88 Control Modules
    - LocoNet-T
    -- Added colorized conflicts in DR5000 feedback space in Feedback monitor
    -- Added RailCom address in Feedback Zone when one or more DR5088RC are connected
    - LocoNet-B
    -- See LocoNet-T
    - XN+FB Bus
    -- Added option "Report feedback from module".
    -Prog Track
    -- CV Read data read from the LocoNet when one or more DR5088RC are connected
    -USB 2.0
    -- Improved automatic insertion and removal of the DR5000 USB cable. (feature is still under development, may crash sometimes upon removal)
    -- Settings are saved before firmware update and restored after firmware update
    -Control
    -- Added Export- and Import buttons for saving and restoring all DR5000 settings
    -- Added Settings page
    * Enable save and restore loco data --> When enabled, pressing STOP button on the DR5000 save the current Loco data, when powering up DR5000 reads back loco data (no connection to PC needed)
    * Data grid for entering address step data per address. Only settings which are not equal to default speed steps are saved.